Raytherm® - Type WH
Job:
Engineer:
Contractor:
Prepared By:
Model:
Water Heaters
Commercial
Models 2100 - 4001
Indoor Date:
EFFICIENT
ꢀ 82% thermal efficiency – highest of any atmospheric
water heater available today
THERMAL SHOCK PROOF
ꢀ Twenty-year warranty against thermal shock damage
up to 150°F differential
ꢀ Maximum operating temperature: 210°F
LIGHTWEIGHT
ꢀ A floor load of 70 lbs./sq. ft. or less
HIGH RECOVERY
ꢀ Cuts fuel costs substantially because the standby
and radiation losses associated with tank-type
water heaters are eliminated
INDOOR
LOW WATER OPERATING TEMPERATURE
ꢀ Operates with water temperature as low as 105°F
without condensing
Heat Exchanger
Gas Control Train
Water Heater Controller
ƒ
ASME Inspected and Stamped
160 PSIG
National Board Approved
Headers
ƒ
ƒ
ƒ
ƒ
ƒ
Manual Main Gas Shut-off Cock
Required on Model WH2 only
B-17 Modulating Controller
(104-220°F), Mounted
By Others
Main Gas Pressure Regulator
Redundant Safety Shut-off Valve
Control Valve
ƒ
ƒ
Bronze – Standard
Firing Mode
Temperature Controllers
B-2 Single-Stage Tankstat
(100-180°F), Loose
Glass-lined Cast Iron – Option A-2
Fin Tubing
On/Off (WH1)
ƒ
2-stage Firing (WH3)
Motorized Modulation (WH2)
Fuel
Natural Gas
Propane Gas
Design Certified ANSI Z21.10.3
Copper – Standard
B-3 2-Stage Tankstat (100-180°F),
Loose
Y-241 Electronic Sequencer,
1-4 Stages
Y-281 Electronic Sequencer,
1-8 Stages
Cupro Nickel – Option A-3
ASME Steel Tube Sheet
Silicone O-Rings
125 PSIG ASME Pressure Relief Valve
Temperature and Pressure Gauge
Water Connections
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
Construction
ƒ
ƒ
ƒ
ƒ
ƒ
Front Controls
Left Hand – Standard
Right Hand – Option A-6
Two-pass Flow Configuration
Additional Safety Controls
Stainless Steel Burners
Baked Enamel Paint
Built-in Draft Diverter
Draft Inducer – Optional
Motorized Draft Inducer –
Indoor – Option D-2
F-9 Low Water Cut-off Probe
ƒ
I-3
High Limit Control, Auto Reset,
180°F
Controls
S-1 Low Gas Pressure Switch,
Manual
S-2 High Gas Pressure Switch,
Manual
ƒ
ƒ
ƒ
ƒ
ƒ
ƒ
120V, 60Hz, 1 Ph Power Supply
120/24V Transformer
100% Pilot Shut-off/Lockout
Electronic, Intermittent Ignition (IID) Pilot
High Limit Control, Manual Reset – 200°F
High Limit Control, Auto Reset – 200°F
Models 3001-4001
Regulatory Agency Requirements
ƒ
ƒ
ƒ
On/Off Switch
Flow Switch
Economaster II Pump Time Delay
CSD-1 Safety Controls
Catalog No.: 3500.24B
Effective: 1-15-08
Replaces: 7-15-04
|
Radio Shack TV Antenna U 75R User Guide
RedMax Blower HB250 User Guide
Reebok Treadmill RBTL698100 User Guide
Renesas Computer Hardware R8C 23 User Guide
Roland Musical Instrument TU 12EX User Guide
Samsung Blu ray Player BD J5100 ZA User Guide
Samsung DVD Player DVD V6500 User Guide
SanDisk Digital Photo Frame Digital Photo Viewer User Guide
Sanyo Cordless Telephone CLT 5810 User Guide
Satco Products Indoor Furnishings S3680 User Guide